What are the requirements for the width of the door of Henan Refuge Room? According to Article 5.5.32 of the Code for Fire Protection Design of Buildings: for residential buildings with a building height of more than 54m, there should be a room that meets the following requirements: it should be set close to the external wall and should be set with an openable external window; The fire resistance limit of the inner and outer walls should not be less than 1.00h. The [] of the room should adopt the Z-grade fire door, and the fire resistance integrity of the outer window should not be less than 1.00h. major Class A fireproof window The total net width of the door, emergency exit, evacuation walkway and evacuation staircase of the residential building with the door of Henan refuge room shall be determined by calculation, and the net width of the door, emergency exit and evacuation staircase shall not be less than 0.90m, and the net width of the evacuation walkway, evacuation staircase and the first floor evacuation shall not be less than 1.10m. The clear width of the evacuation staircase with railings on one side of the residence with a building height of no more than 18m shall not be less than 1.0m. Class A fireproof window direct deal The relevant requirements of the Code for Fire Protection Design of Buildings stipulate that: 1. For the auditorium, exhibition hall, multi-function hall, restaurant, business hall, etc. with no less than 2 evacuation [] or emergency exits in buildings of Class I and II fire resistance rating, the straight-line distance from any indoor point to the evacuation door] or emergency exit shall not be more than 30 m.

The introduction of Henan fire rolling shutter door is a kind of fire prevention and heat insulation facilities suitable for large openings of buildings. The product has played a certain role in the design and installation of technology. major Class A fireproof window Fire resistant rolling shutter doors are widely used in the fire partition area of industrial and civil buildings, which can effectively prevent the spread of fire and ensure the safety of life and property. They are indispensable fire prevention facilities in modern buildings. Installation requirements and instructions for fire shutter door 1. The upper part of the opening where the shutter door is installed shall not be equipped with ventilation pipes, water pipes, etc; 2. After the roller shutter door is installed, install the suspended ceiling. The edge of the suspended ceiling should be 50mm away from the curtain plate to avoid friction; 3. During commissioning and use, it is strictly prohibited to stand at the bottom. Class A fireproof window direct deal Electrical facilities shall not be removed without authorization; 4. According to the fire management regulations, the chain lubricating oil of the starting motor must not be missed during the routine fire safety inspection every quarter, which is also an important part of the omission of many property management units or fire protection units during the inspection.

Henan fireproof door installation method The fireproof door is divided into steel fireproof door and wooden fireproof door according to the material. There are some differences in the installation method of the two fireproof doors. major Class A fireproof window The fire rating is slightly different. You must pay attention to the details when installing. First of all, when installing the wooden fireproof door, the size of the door frame should be 20mm smaller than the opening, and the lower foot of the door frame should be buried 20mm below the ground. The door frame should be firmly fixed with the wall, and perpendicular to the corner. The vertical frame and bracing frame shall be straight and at the same angle to avoid planing and sawing. There shall be no less than 3 fixed points on both sides of the door frame, and the spacing shall not be greater than 800mm. Secondly, during the installation of the steel fire door, considering the bending deformation of the door frame, it is necessary to support the door frame with wooden braces in the width direction of the door frame. The lower foot of the door frame is buried 20 mm below the ground, and then the door frame is welded with the embedded parts on the wall. Then make a hole in the wall at the upper corner of the door frame, and pour concrete of cement, sand and expanded perlite (1:2:5), which can be used after the concrete has set. Class A fireproof window direct deal Requirements for airtightness of fire doors: there are clear requirements for the size of the gap at each overlap of fire doors: for steel fire doors, the overlap between the leaf and the door frame shall not be less than 10mm, and the gap between the leaf and the door frame on both sides shall not be more than 4mm. The gap after the installation of the fire door cannot be too large, otherwise the airtightness of the fire door is difficult to guarantee, and it is difficult to reflect its role in restraining fire and smoke spread under fire conditions.

Henan fireproof rolling shutter door maintenance common faults and treatment methods The fireproof rolling shutter door is constantly applied to large supermarkets, shopping malls, underground garages, workshops and other crowded places. It is inevitable that there will be some small problems that need to be solved. I summarize a few points for your reference. 1、 The fire shutter door does not act: first, check the power supply to see if the power supply air switch of the fire shutter door has power. If there is no power, check the power supply. If there is power, the power indicator of the roller shutter control box should be green at this time. major Class A fireproof window If the indicator light is not on, then we should check whether the transformer in the control box (the resistance of the transformer is 270 ohms) is burned out. If the power indicator flashes green, it indicates that the power supply may be out of phase. If the power supply is not out of phase, it may be that the standby power board of the control box is burned out; It is also possible that both the power board and the standby power board are burned out. 2、 Henan fire shutter door power supply air switch cannot be pushed up: when delivering the gate, the air switch cannot be pushed up, first check whether there is a problem with the standby board, and the resistance of the output line of the standby board is about 300 ohms. In case of open circuit or short circuit, check whether the motor brake is burnt or whether the spare board is burnt. 3、 The operation button does not work properly: you should first press the Stop key, then press the Reset key, and then press the Up and Down keys. 4、 The indicator lights of the power control box or button panel are all on: at this time, first check whether there is a short circuit in the button line or a button may be pressed to death. If the above phenomenon does not exist, it may be that the chip on the power main board is broken, and then replace the chip. Class A fireproof window direct deal Pay attention to wearing the clothes in reverse (that is, the opening faces the opening).

The main difference between Henan fireproof door and anti-theft door is that the anti-theft door has a good anti prying sealing performance. Generally, the door cannot be opened without a key after closing the door. The filler in the door panel is not fireproof material. major Class A fireproof window The security door must be marked with "FAM" and refer to the general technical conditions of security door GB17565-2007. Although the fireproof door is also made of steel, the door plate is filled with fireproof materials, and the thickness of the door plate also has different requirements. The steel door is an ordinary steel door. It also has a certain anti-theft function, but its anti prying performance is relatively poor. This type is common in street processing plants. Only Shanghai and Chengdu have local standards for fire and burglar proof doors, and those in other places can only be called fire entry doors, that is, fire doors that reach the standard of fire rated A or B, and (filled with fire door cores) Class A and B standards are generally divided by fire resistance time. At the same time, it meets the anti prying requirements in the following aspects: the door frame is 1.5 thick, and the steel plates on the front and back of the door leaf are 0.8 thick. The lock has the anti prying function, that is, the lock body has both an oblique locking tongue and a square locking tongue. It has the function of quick opening. It is a good twist type, but it is not allowed to install a heaven and earth lock. Locks and cat eyes shall be provided with fire detection reports. Class B fire doors can be fitted with door collars, while Class A fire doors are not allowed. Class A fireproof window direct deal At the time of acceptance, the merchant must provide fire type approval certificate, fire detection report and metal door detection report. Fire detection report of locks and cat's eyes. The door leaf is opened in the direction of rapid evacuation and cannot be opened inward.